view construction G-CO-C guide rail for DC700 door closer

Required space on doors

Active leaf DIN right shown in the diagram
Active leaf DIN left is the reverse
GF* = Active leaf
SF* = Passive leaf

Installation dimensions

Active leaf DIN right shown in the diagram
Active leaf DIN left is the reverse
GF* = Active leaf
SF* = Passive leaf

Mounting plate A180

Angle bracket A181

Carry bar A102

Enables the correct opening sequence of double doors, installed to inactive door leaf on non-hinge side
(G461/G462/G464 installed on non-hinge side)
The length of A102 is even adjustable from 320 - 360 mm, consequently an adjustable range of 40 mm.

Mechanical Hold-Open Device A158

Mechanical hold-open device for temporarily holding doors open
Simple fitting into guide rail G-CO und G-GO-C
Doors held open at an opening angle of 130/110° hinge side/non-hinge side
Continuously adjustable holding force
Not approved for use on fire and smoke protection doors

Opening damper A188

Helps to prevent the door and door handle from hitting a return wall.
Simple installation in the guide rail, but doesn´t replace the need for a door stop